“The outbreak of avian influenza A (H5N1) virus has raised


“The outbreak of avian influenza A (H5N1) virus has raised a global concern for both the animal as well as human health. Besides vaccination, that may not achieve full protection in certain groups of patients, inhibiting neuraminidase or the transmembrane protein M2 represents the main measure

of controlling the disease. Due to alarming emergence of influenza virus strains resistant to the currently available drugs, development of new neuraminidase N1 inhibitors is of utmost importance. The present paper provides an overview of the recent advances this website in the design of new antiviral drugs against avian influenza. It also reports findings in binding free energy calculations for nine neuraminidase N1 inhibitors (oseltamivir, zanamivir, and peramivir -carboxylate, -phosphonate, and -sulfonate) using the Linear Interaction Energy method. Molecular dynamics simulations of these inhibitors were performed in a free and two bound states the so called open and closed conformations of neuraminidase N1. Obtained results successfully reproduce the experimental binding affinities of find more the already known neuraminidase N1 inhibitors, i.e. peramivir being a stronger binder than zanamivir that is in turn stronger binder than oseltamivir, or phosphonate inhibitors being stronger binders than their carboxylate analogues. In addition, the newly proposed sulfonate inhibitors are predicted to

be the strongest binders – a fact to be confirmed by their chemical synthesis and a subsequent test of their biological activity. Finally, contributions of individual inhibitor moieties to the overall binding affinity are explicitly evaluated to assist further drug development towards inhibition of the H5N1 avian influenza A virus.”
“BACKGROUND: When an anterior approach to repair a burst fracture is indicated, several devices can be used to restore spinal stability (eg, bone graft, free-standing titanium cage, and expandable titanium cage).\n\nOBJECTIVE:

We compare the biomechanical stability and prices of each of these systems.\n\nMATERIALS AND METHODS: Eight fresh human cadaver T11 through L3 vertebral specimens were harvested and cleaned of soft tissues. T11-T12 and L2-L3 were fixed by screws. The fixed ends were then set in automotive body filler (Bondo). selleck products The prepared specimens were tested in the Biaxial Instron tester (8874, Norwood, MA) after a sequence of the following: intact, after the creation of an anterior corpectomy at L1, and after insertion of both of the 2 different titanium cages and the fibular graft. A titanium screw-and-plate anterolateral system was used to secure the construct (VANTAGE, Medtronic Sofamor Danek, Memphis, TN). The conditions of displacement testing were as follows: rotation (+/- 3.5 degrees), flexion and extension, and left and right bending (+/- 3.5 mm). For each mode of testing, the stiffness was calculated.

Comments are closed.