In addition, the Ti contents in the stock suspension, drinking water, and food were also analyzed. The lungs after BALF sampling, kidneys, and spleen were homogenized with 2 mL of ultrapure water (Milli-Q Advantage
A10 Ultrapure Water Purification System, Merck Millipore, USA), and the liver was homogenized with 10 mL of ultrapure water. An electric homogenizer (PT10-35 Kinematica AG and NS-50; Microtec Co. Ltd., Japan) was used and the resulting homogenates were stored at <−30 °C until analysis. All samples were treated with acid prior to determination of Ti levels. Nitric acid (HNO3; 68%, 0.5 mL) and hydrogen peroxide (H2O2; 35%, 0.2 mL) were added to 0.1 mL of BALF, HNO3 (1 mL), and sulfuric acid (H2SO4; 98%, 0.2 mL) were added to 1 g of homogenized this website tissues, HNO3 (0.5 mL) and H2SO4 (0.1 mL) were added to whole lymph node samples, HNO3 (1 mL) and H2O2 (0.3 mL) were added to
0.02 g of animal feed, and H2SO4 (0.5 mL) and hydrofluoric acid (HF; 38%, 0.5 mL) were added to 20 μL and 100 μL for high and low concentrations of the administered TiO2 suspension, respectively. Drinking water was diluted 10-fold with 10% HNO3 solution, with no subsequent handling. All acids used in the present study were ultrapure grade reagents (TAMAPURE-AA-100, Tama Chemicals Co., Ltd., Japan). The acidified samples (apart from drinking water) were placed in a 7 mL perfluoroalkylvinylether vessel, which was inserted into a 100 mL digestion vessel of a microwave sample preparation instrument (ETHOS 1; Milestone Srl
Alectinib purchase Italy or Speedwave 4; Berghof, Germany), and they were heated to 180 °C for 20 min or 200 °C for 20 min. After cooling to 40 °C, the acid-treated samples, with the exception of the TiO2 nanoparticle suspensions, were diluted to 5 mL (BALF and lymph nodes) or 10 mL (the other organs and feed) with ultrapure water (made by PURELAB Option-R 7 and PURELAB Flex UV from Veolia Water Solutions and Technologies, click here France). Samples of the acid-treated TiO2 nanoparticle suspensions were heated on a hotplate for approximately 2 h until white fuming sulfuric acid was generated. After cooling, the solution was diluted to 50 mL with 10% HNO3. The sample Ti contents were then determined by ICP-SFMS using a Finnigan ELEMENT II (Thermo Fisher Scientific Inc. , Germany), and the Ti content in the administered TiO2 nanoparticle suspensions was determined by ICP atomic emission spectrometry (ICP-AES; SPS4000, SII NanoTechnology Inc., Japan). For ICP-SFMS, RF power was 1250 W, cool gas flow rate was 16 L/min, auxiliary gas flow rate was 0.87 L/min, sample gas flow rate was 0.870–0.965 L/min, additional gas flow rate was 0.080–0.180 L/min, mass resolution (R) was 4000, and the measured mass number m/z was 49. For ICP-AES, RF power was 1.3 kW, plasma gas flow rate was 16 L/min, additional gas flow rate was 0.5 L/min, carrier gas flow rate was 1.0 L/min, and wavelength was 334.941 nm. In the present study, 49Ti (mass: 48.