In addition, the Ti contents in the stock suspension, drinking wa

In addition, the Ti contents in the stock suspension, drinking water, and food were also analyzed. The lungs after BALF sampling, kidneys, and spleen were homogenized with 2 mL of ultrapure water (Milli-Q Advantage

A10 Ultrapure Water Purification System, Merck Millipore, USA), and the liver was homogenized with 10 mL of ultrapure water. An electric homogenizer (PT10-35 Kinematica AG and NS-50; Microtec Co. Ltd., Japan) was used and the resulting homogenates were stored at <−30 °C until analysis. All samples were treated with acid prior to determination of Ti levels. Nitric acid (HNO3; 68%, 0.5 mL) and hydrogen peroxide (H2O2; 35%, 0.2 mL) were added to 0.1 mL of BALF, HNO3 (1 mL), and sulfuric acid (H2SO4; 98%, 0.2 mL) were added to 1 g of homogenized this website tissues, HNO3 (0.5 mL) and H2SO4 (0.1 mL) were added to whole lymph node samples, HNO3 (1 mL) and H2O2 (0.3 mL) were added to

0.02 g of animal feed, and H2SO4 (0.5 mL) and hydrofluoric acid (HF; 38%, 0.5 mL) were added to 20 μL and 100 μL for high and low concentrations of the administered TiO2 suspension, respectively. Drinking water was diluted 10-fold with 10% HNO3 solution, with no subsequent handling. All acids used in the present study were ultrapure grade reagents (TAMAPURE-AA-100, Tama Chemicals Co., Ltd., Japan). The acidified samples (apart from drinking water) were placed in a 7 mL perfluoroalkylvinylether vessel, which was inserted into a 100 mL digestion vessel of a microwave sample preparation instrument (ETHOS 1; Milestone Srl

Alectinib purchase Italy or Speedwave 4; Berghof, Germany), and they were heated to 180 °C for 20 min or 200 °C for 20 min. After cooling to 40 °C, the acid-treated samples, with the exception of the TiO2 nanoparticle suspensions, were diluted to 5 mL (BALF and lymph nodes) or 10 mL (the other organs and feed) with ultrapure water (made by PURELAB Option-R 7 and PURELAB Flex UV from Veolia Water Solutions and Technologies, click here France). Samples of the acid-treated TiO2 nanoparticle suspensions were heated on a hotplate for approximately 2 h until white fuming sulfuric acid was generated. After cooling, the solution was diluted to 50 mL with 10% HNO3. The sample Ti contents were then determined by ICP-SFMS using a Finnigan ELEMENT II (Thermo Fisher Scientific Inc. , Germany), and the Ti content in the administered TiO2 nanoparticle suspensions was determined by ICP atomic emission spectrometry (ICP-AES; SPS4000, SII NanoTechnology Inc., Japan). For ICP-SFMS, RF power was 1250 W, cool gas flow rate was 16 L/min, auxiliary gas flow rate was 0.87 L/min, sample gas flow rate was 0.870–0.965 L/min, additional gas flow rate was 0.080–0.180 L/min, mass resolution (R) was 4000, and the measured mass number m/z was 49. For ICP-AES, RF power was 1.3 kW, plasma gas flow rate was 16 L/min, additional gas flow rate was 0.5 L/min, carrier gas flow rate was 1.0 L/min, and wavelength was 334.941 nm. In the present study, 49Ti (mass: 48.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>